Add to Cart
ISO20653 High-Pressure Open-Type Spray IPX9K Waterproof Test Equipment
Complied Standards & Clauses
Conforms to IEC60529, DIN40050-9, ISO20653, and other standards.
Equipment Overview
This equipment is designed to test a wide range of specimens, including passenger cars, buses, lamps, motorcycles, and various vehicle components.
It accurately replicates high-pressure and steam jet cleaning conditions to assess the physical and related properties of the specimens.
Following the test, the performance of the product can be evaluated against specified standards, aiding in design optimization, performance enhancement, compliance verification, and quality control inspections.
Technical Parameters
IPX9K | |
User site requirements |
|
Test sample | Maximum length, width and height ≥1200x1200x1200mm, maximum sample weight ≥80kg. |
Number of nozzles | The system is equipped with two precision nozzles strategically positioned for comprehensive coverage:
The spray trajectory follows an S-shaped path, ensuring uniform and thorough coverage. A four-way servo motor system enables precise control, facilitating 5-sided water spraying for comprehensive testing. |
Four nozzle apertures | 2.34*1.33mm (oval) |
Nozzle distance | 150-200mm |
Spray angle | The spray can cover the entire surface of the sample, and the spray angle is perpendicular to the sample surface. |
Water pressure | 8-10MPA |
Water temperature | 80℃±5℃ |
Flow meter | Electronic high pressure flow meter |
Pressure gauge | High pressure meter |
Hydraulic pipe | 3m long |
Flow rate | 15L±1/min |
Test Method | (1) The top and five surfaces of the test sample are sprayed with water in turn. (2) When the shell is tested in test a) and test b), the water temperature should be maintained at (80±5)℃. (3) For small enclosures (maximum size ≤ 250 mm): The enclosure should be installed on the test device. Rotation speed: (5±1) r/min. Spray angle: 0°, 30°, 60°, 90°. The test time for each position is 30 seconds. (4) For large enclosures (maximum size ≥ 250 mm): The enclosure should be installed according to the intended use. The entire outer surface of the enclosure will be sprayed. Spray direction: Spray from all directions to cover the entire surface of the enclosure. The spray angle should be as perpendicular to the spray surface as possible. The distance between the nozzle and the test sample under test conditions is (175±25) mm, at least 3 minutes. |
Water spraying time | The basic reference test time is 2 minutes per square meter. The time to complete the entire track can be set. It can be set in about 500 seconds (3.96 square meters). When setting, you can enter the dimensions according to the product's overall dimensions of length, width and height, and the system will automatically complete the test running track for orderly testing. After the test is completed, the nozzle returns to the origin, and the device gives an audible and visual prompt. |
High-pressure water pump | Italian WOKE brand |
Rack moving stroke | 2 meters, one meter on each side |
Nozzle working mode | 175±25mm (adjustable). Equipped with electric nozzle mobile frame. The nozzle can be moved forward, backward, left, right, up and down, and the nozzle angle can be rotated. |
Constant temperature water tank | An independent constant temperature water tank of about 500L. It can meet the continuous water spraying time of about 30 minutes. |