Add to Cart
IEC 62916-3 EV Plug and Socket Temperature Rising Test Equipment
Complied Standards & Clauses
It is designed and manufactured according to IEC 61851-1:2017 clause 11.6.
Equipment Overview
The system uses self-programmed software controlled by a computer. All standard test procedures and data judgments are controlled by the system, making operation easy. It is used to assess the surface heating and electrode temperature rise of charging interfaces and electrical accessories when connected to load current and to check if the temperature rise meets the standard requirements.
It is suitable for detecting the temperature rise test after the EV plug and socket pass the rated current, assessing the heating of the surface of the electrical accessories when the load current is connected, and whether the temperature rise of the terminal meets the requirements of the standard. Also used for short-time high current withstand tests for grounding contacts.
Technical Parameters
Continuous On/Off Mode | 1. Continuous Mode Test Time: 0.01–99.99 hours 2. On/Off Mode Power On/Off Time: 0.01–99.99 hours 3.On/Off Count: 1–9999 times, stops automatically when the count is reached 4.Current Setting: Programmable control settings (can be configured according to IEC62196, with time and current combinations as shown in the table below) |
Maximum Output Voltage | DC less than DC 15V |
Operating Modes |
|
Current Display Accuracy | ±(0.25% of reading + 0.25% of range), resolution 1A |
Voltage Display Accuracy | ±(0.25% of reading + 0.25% of range), resolution 0.01V |
Test Current Stability | ±(1% of set value + 0.5A), response time approximately 1s |
Control Contact Power Supply | Current range AC (0–2) A |
Output Workstation | 1 DC output station |
Constant Adjustable Test Current Output | DC 200–6500A |
Automatic Temperature Control Mode | The system can set a stable temperature rise value and automatically find the appropriate current value. Automatically calculates the required current for the desired temperature rise |
Temperature Rise Setting Range | 0–100°C |
Stability Accuracy | ±0.5°C |
Voltage Drop and Resistance Testing Function | The equipment is configured with an mV meter that can detect voltage drop across the connector and calculate the corresponding resistance value. |
Power Supply | AC 220V ±10%, 50/60Hz, 50KVA |
Dimensions | Approx. 1000mm (W) × 1300mm (D) × 1800mm (H) |
Weight | Approx. 400kg |