Add to Cart
1KW Elevator Cable Center Core Tensile Expansion Strength Testing Machine
Complied Standards & Clauses
Conforms to IEC60245-1-2008 clause 5.6.3.4, IEC60245-2-1998 clause 3.4, IEC60227-1:2007 clause 5.6.3.4, IEC60227-2:2003 clause 3.4 and clause 3.6.
Product Overview
Samples and restrictions: Elevator cable center core.
Application: Expansion strength test for elevator cable center core.
Test principle: Configure the tension clamp, take a 1m long sample from the finished cable and weigh it. Peel off all coverings within 0.2m from both ends of the specimen and remove the insulated wire core. The central pad core including the central load-bearing core should withstand a tensile force equivalent to the mass of 300m of cable. The pulling force should be applied for 1 minute.
Usage environment: Power supply: AC220V±10%/50-60Hz 1kW , operating temperature 0-40℃, humidity 30%-90%;
Technical Parameters
Equipment dimensions | About: 500×500×1600 (mm) W×D×H |
Equipment weight | 100kg |
Maximum test force | 2000N |
Test force display range | 0~500kg |
Test force classification | There is no binning throughout the process, and the resolution remains unchanged throughout the process. |
Test force measurement accuracy | Better than ±1% of the indication value |
Displacement resolution | 0.01mm |
Displacement measurement accuracy | Better than ±1% of the indication value |
Crossbeam moving speed range | 25mm/min~500mm/min stepless speed regulation, speed can be set arbitrarily |
Displacement speed control accuracy | Better than ±1% |
Stretch space | 0~1000mm |
Power supply | AC220V±10%/50-60Hz 1kW |
Operating temperature | 0-40℃ |
Humidity
| 30%-90% |
Details