Add to Cart
EMC Test Solution for Automotive ESA Electric Vehicle Testing Equipment
Complied Standards & Clauses
UN ECE R10 "Uniform Provisions Concerning the Approval of Vehicles with Regard to Electromagnetic Compatibility"
EN 55025/CISPR 25 "Vehicles, boats and internal combustion engines- Radio disturbance characteristics- Limits and methods of measurement for the protection of on-board receivers"
CISPR 12 "Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers"
ISO 11452 "Road vehicles-Component test methods for electrical dusturbances from narrowband radiated electromagnetic energy"
ISO 10605 "Road vehicles — Test methods for electrical disturbances from electrostatic discharge"
SAE J1113 "Electromagentic Compatibility Measurement Procedure and Limits for Vehicle Components (Except Aircraft) (60Hz to 18GHz)"
EN 50498 "Electromagnetic compatibility (EMC)-Product family standard for aftermarket electronic equipment in vehicles"
EN301489-1: "ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements"
EN55032: " Electromagnetic compatibility of multimedia equipment - Emission requirements"
IEC 61000-3-2: "Electromagnetic compatibility limits for harmonic current emissions (equipment input current ≤16A)"
IEC 61000-3-3: "Electromagnetic compatibility limits the voltage variation produced with rated current ≤16A and unconditional access of the device in public low-voltage power supply system, voltage fluctuations and flicker limits"
......
System Overview
The whole test system includes EMI test project and EMS test project shown as following:
Test items | Test content | Test site |
Conduction Emission | 150kHz-30MHz, QP / AV | Shielded room |
Radiated Emission | 30MHz-6GHz, QP / AV | Shielded room |
Harmonic current emissions | According to IEC61000-3-2 | Ordinary laboratory |
Voltage fluctuations and flicker | According to IEC61000-3-3 | Ordinary laboratory |
Test items | Test content | Test site |
ESD test | According to IEC61000-4-2 | Ordinary laboratory |
EFT test | According to IEC61000-4-4 | Ordinary laboratory |
Conducted RF immunity | According to IEC61000-4-6 | Shielded room |
RF radiated immunity test | According to IEC61000-4-3 | chamber |
Surge immunity test | According to IEC61000-4-5 | Ordinary laboratory |
Voltage dips, short interruptions and voltage variations immunity | According to IEC61000-4-11 | Ordinary laboratory |
ISO 7637 test Automotive Electronics Test Project (For Automotive parts) | According to ISO 7637 pulses 1, 2a, 2b, 3a, 3b, and 4 | Ordinary laboratory |
The system consists of an SAC, a control room and an amplifier room:
NO. | Item | Specification (outer size) | QTY |
1 | Anechoic Chamber | 9.2 × 6.2× 6.2m (L × W × H) (Adjustment is according to the structural of the building, cost will be different) | 1 |
2 | Control Room | 3.0 × 3.0 × 3.0m (L × W × H) (Adjustment is according to the structural of the building, cost will be different) | 1 |
3 | Amplifier Room | 2.0 × 3.0 × 3.0m (L × W × H) (Adjustment is according to the structural of the building, cost will be different) | 1 |