Sinuo Testing Equipment Co. , Limited

Sinuo Testing Equipment Co., Limited

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Flammability Testing Equipment /

IEC 60332 Single Insulated Cable Vertical Flammability Chamber

Contact Now
Sinuo Testing Equipment Co. , Limited
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsZoe Zou
Contact Now

IEC 60332 Single Insulated Cable Vertical Flammability Chamber

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN775
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :30 days
Price :Customized
Supply Ability :30 sets/month
Packaging Details :Plywood Case
Applied Standard :IEC 60332-1-1, etc.
Test Sample :Single insulated wire or cable
Combustion Burner :Φ7±0.05mm brass burner
Burning Angle :Tilt 45°±2°, adjustable
Thermocouple Type :φ0.5mm Omega K type
Heating Time :100±5°C to 700°±3°C is 45±5s
Inner Flame Height :55±5mm
Outer Flame Height :180±10mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60332 Single Insulated Cable Vertical Flammability Test Chamber

Complied Standards & Clauses


IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus”

IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame”

IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flamingdroplets/particles”

Equipments Overview


Samples and Restrictions: Single insulated wire or cable.

Application: It is suitable for vertical burning test of a single insulated wire, cable or optical fibre cable to determine the burning characteristics of its insulating material.

Test Principle: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.

Structure: Chamber structure, fume hood is optional.

Technical Parameters


Control and Operation Mode

Electric control button operation

(PLC control 7-inch color touch screen operation is optiona)

Burner IEC 60695-11-2 Annex A, burner opening Φ7±0.05mm, made of brass
Gas Flow and Gas Source Type Mixed gas: 650±30mL/min propane; 10±0.5L/min air, adjusted by dual flow meters
Burning Time 9999X0.1S
Burning Angle Tilt 45°±2°, adjustable
Test Flame Verification Temperature measuring copper head: 500W: Ф9mm±0.01mm, 10±0.05g before drilling
Thermocouple: American original Omega φ0.5 armored nickel-chromium/nickel aluminum wire, K type, temperature resistance 1100°
Distance between Bunsen burner port and temperature measuring copper block: 95 mm
Flame height: inner flame 55±5mm, outer flame 180±10mm
The heating time from 100±5°C to 700°±3°C is 45±5s
Test chamber Dimension WDH=300×450×1200±25mm
Gas >95% propane gas or coal gas
Requirements of Sample Length: 600±25mm, 50mm from the bottom of the chamber
Horizontal Support Sample Fixtures Two, distance 550mm
External Dimensions WDH=1100×600×1550mm,Weight about 160kg, equipped with fume hood