IEC 60068 Walk In Temperature Humidity Environmental Test Chambers

Ask Latest Price
Video Channel
Brand Name :Sinuo
Model Number :SN886
Certification :Calibration Certificate (Cost Additional)
Place of Origin :China
MOQ :1
Payment Terms :T/T
Delivery Time :45 days
Price :Customized
Supply Ability :20 sets/month
Packaging Details :Other
Applied Standard :IEC 60068 series
Control & Operation :PLC and touch screen
Temperature Range :Can be customized
Humidity Range :30%〜98%RH
Heating Rate :≤2.5°C/min
Cooling Rate :Average 1.0 ° C / min
Temperature Deviation :≦±2.0℃
Humidity Deviation :±5.0%RH
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60068 Walk In Temperature Humidity Environmental Test Chambers

Complied Standards & Clauses


IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle) , IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

Equipment Overview


The walk-in test chambers simulate the temperature and humidity changeable environment for the products or materials. They are widely used in the adaptability test of electrical, electronics, instrument and meter and other product parts under high and low temperature and humid environment during storage, transportation and usage, to determine the temperature adaptability of the above products or materials to high and low temperature and humid environment, especially for product electrification changes in performance and mechanical properties.

Technical Parameters


Control & Operation PLC and touch screen intelligent control system
Chamber Size (Optional)

8m3: WDH=2×2×2m

12m3: WDH=3×2×2m

20m3: WDH=2×2×5m

50m3: WDH=5×2×5m

Other dimensions can be customized

Temperature Range (Optional)

Maximum test temperature: 80 ° C, 120 ° C;

Minimum test temperature: -60 ° C, -40 ° C, -20 ° C, 0 ° C

Temperature Deviation ≦±2.0℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2℃
Humidity Range 30%〜98%RH
Humidity Deviation ±5.0%RH
Heating Rate ≤2.5°C/min (nonlinear, no load)
Cooling Rate Average 1.0 ° C / min